Free Sitemap Generator

China National Electric Wire & Cable Import & Export Corp.

Quality, Efficient and Cost

Google
Free Sitemap Generator

Steam Turbine

As a China steam turbine provider, we can provide our customer condensing, back pressure, extraction, extraction-back pressure, geothermal, wet steam, multi-pressure, industrial and packaged modular units, including more than 200 types, which find a wide application in many industries such as power generation, petroleum, chemistry, printing and dying, textile, cement, pulp and paper, sugar refinery, steel and iron, garbage disposal, combined steam and gas turbine cycle, and urban district heating, and, user’s different requirements can also be satisfied to the utmost extent.

These steam turbines are made in China by integrated technology from China and the world. 
  

We offer the following China steam turbines:

1. Condensing Steam Turbine

2. Mixed Pressure Steam Turbine

3. Back Pressure Steam Turbine

4. Extraction Back Pressure Steam Turbine

5. Geothermal Steam Turbine

6. Low-level Recovery Steam Turbine

7. Double Extraction Condensing Steam Turbine

 

There is one example form of our specification of condensing steam turbine

TABLE 1  TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES                  1-1

 

No.

         Designation & code

 

Item              Unit  

6MW

*25MW

25MW

50MW

**55MW

1

Code

 

78#

SX22#

124#

06#

109#

2

Model

 

N6-3.43/435

N25-0.98/270

N25-3.43/435

N50-8.83/535

N55-8.83/535

3

Type

 

Impulse tandem- comp.1-cylinder

1-exhaust

Impulse tandem- comp.1-cylinder

1-exhaust

Impulse tandem- comp.1-cylinder

1-exhaust

Impulse tandem- comp.1-cylinder

1-exhaust

Impulse tandem- comp.1-cylinder

1-exhaust

4

Rated output

MW

6

25

25

50

55

5

Max.output

MW

 

30

30

55

60

6

Speed

r/min

3000

3000

3000

3000

3000

7

Steam pres.before stop valve

Mpa

3.43

 

3.43 +0.098

     -0.196

8.83

8.83±0.49

8

Steam temp.before stop valve

435

270  +10

     -5

435

535

3.43 +5

     -10

9

Rated steam flow

t/h

30

160

108

190

204/211(exhaust)

10

Max steam flow

t/h

 

190

130

210

224

11

Reheat steam temp.

 

 

 

 

 

12

Exhaust steam temp.

Mpa

0.0081

Winter 0.049

Summer 0.0093

0.0044

0.0049

0.0056

13

Cooling water temp.

27

Win.60/Sum.26

20

20

20

14

No. of stages

 

1+8

1+8

1+8

1+8

1+8

15

No. Of heaters

 

1(HP heater)

+1(deaerator)

+1(LP heater)

2(LP heater)

deaerator and HP heater equip.

2(HP heater)

+1(deaerator)

+1(LP heater)

2(HP heater)

+1(deaerator)

+4(LP heater)

2(HP heater)

+1(deaerator)

+3(LP heater)

16

Feed water temp.

165.3

128

175

222

215

17

Heat rate

KJ/kW. H

13060

Winter 20879

Summer 16480

11087

9466

9488/9000

(exhaust)

18

Steam rate

Kg/kW.h

5.02

Winter 8.632

Summer 6.741

4.40

3.75

3.71

4.21(exhaust)

19

Last vane’s height

mm

270

432

432

665

668

20

Overall size

(L x W x H)

m

4.0x2.6x2.3

6.7x4.3x2.5

7.2x4.4x3.3

8.7xx6.9x3.4

9.48x6.96x3.5

21

Turing wt.

T

23

80

45

123

144

22

Max.lifting wt.

During erection

t

 

21

18.7

40

27.5

23

Cooling surface of condenser

m2

560

2600

2250

3500

3500

Remark

l        Operation at high pressure in winter, heat provided by cycle water.

l        55MW condensing steam turbines, with not adjustable exhaust, exhaust pressure 0.981Mpa,exhaust capacity 30t/h.

 

 

TABLE 1   TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES                  1-2

 

No.

       Designation & code

 

Item              Unit  

*50MW

**75MW

100MW

***100MW

125MW

1

Code

 

53#

126#

43#

43A#

 

2

Model

 

N50-8.83/535

N75-1.42/274

N100-8.83/535

N100-8.83/535

N125-13.2/535/535

3

Type

 

Impulse tandem- comp.1-cylinder

1-exhaust

Impulse tandem- comp.2-cylinder

2-exhaust

Impulse tandem- comp.2-cylinder

2-exhaust

Impulse tandem- comp.2-cylinder

2-exhaust

Impulse tandem- comp.2-cylinder

1-exhaust

4

Rated output

MW

50

75

100

100

125

5

Max.output

MW

55

78.5

112

112

135

6

Speed

r/min

3600

3000

3000

3000

3000

7

Steam pres.before stop valve

Mpa

8.83

1.42

8.83

8.83

13.2

8

Steam temp.before stop valve

535

274

535

535

535

9

Rated steam flow

t/h

193

386

370

360

379

10

Max steam flow

t/h

213

405

417

420

420

11

Reheat steam temp.

 

 

 

 

535

12

Exhaust steam temp.

Mpa

0.0049

0.0054

0.0049

0.0047

0.0064

13

Cooling water temp.

20

20

20

20

25

14

No. of stages

 

1+17

6

1+14+5x2

1+16+5x2

1+11+14

15

No. Of heaters

 

2(HP heater)

+1(deaerator)

+3(LP heater)

1(LP heater)

.

2(HP heater)

+1(deaerator)

+4(LP heater)

2(HP heater)

+1(deaerator)

+4(LP heater)

3(HP heater)

+1(deaerator)

+3(LP heater)

16

Feed water temp.

220

60

227

231

248

17

Heat rate

KJ/kW. H

9400

13860

9254

8835

8223

18

Steam rate

Kg/kW.h

3.85

5.15

3.69

3.60

3.03

19

Last vane’s height

mm

610

1000

665

668

855

20

Overall size

(L x W x H)

m

8.1x6.9x3.4

8.0x7.7x3.4

14x6.9x4.7

14x6.9x4.7

13.5x7.8x5.5

21

Turing wt.

T

113

95

256

260

300

22

Max.lifting wt.

During erection

t

40

50

65

66

70

23

Cooling surface of condenser

m2

3500

10000

6815

7000

5600

Remark

l        Operation at high pressure in winter, heat provided by cycle water.

l        55MW condensing steam turbines, with not adjustable exhaust, exhaust pressure 0.981Mpa,exhaust capacity 30t/h.

 

 

For detailed techincal data of some types of steam turbines, please click for downloads:

Cogeneration

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (6MW-200MW Cogeneration)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (1.5MW-3MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (6MW-12MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (12MW-25MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (25MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (25MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (25MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (50MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (50MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (50MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (58M-100MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (60MW-80MW)

Combined

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (47MW-70MW Combined Cycle)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (25MW-190MW)

TECHNICAL SPECIFICATION OF CONDENSING STEAM TURBINES (2.2MW-32MW Industrial Steam Turbine)